ASTM A 269 - 88 a /ASTMA269-88a
Tiancheng Group_Steel-Tube.com   2008-03-21 07:48:27 Author:Josen Dong Source: Font size:[Large][Middle][Small]

ASTM A269-88a SEAMLES AND WELDED AUSTENITIC STAINLESS STEEL TUBING FOR GENERAL SERVICE
(ASTM A 269 - 88 a /ASTMA269-88a)



1. Scope

1.1 This specificatioin covers grades of nominal-wall-thickness stainless steel tubing for general corrosion-resisting and low-or high-temperature serviec, as designated in Table 1.

1.2 The tubing sizes and thicknesses usually furnished to this specification are 1/4. (6.4mm) in inside diametrer and larger and 0.020 in. (0.51mm) in nominal wall-thickness and heavier.

1.3 Mechanical property requirements do not apply to tubing smaller than 1/8. (3.2mm) in in side diameter or 0.015 in.(0.38mm) in thickness

Note 1-When the inpact test criterion for a low-temperature service woluld be 15 ftlbf(20J) energy absorption or 15 mils lateral expansion, some of the austenitic stainless steel frades covered by this specification are accepted by certain pressure vessel or piping codes without the necessity of making the actual test. for example, Frades 304, 304L, and 347 are accepted by the ASME Pressure Vessel Code, Section シ Division 1, and by ANSI B31.3, for service at temperatures as low as -425⒌(-254∩)without qualification by impact tests. Other AISI stainless steel frades are usually accepted for service temperatures as low as -325⒌(-198∩)without impact testing. Impact testing may, under certain circumstances, be required, be required. For example, materials with chromium or nickel content outside the AISI range, and for material with carbon content exceeding 0.10% are required to be impact tested under the rules of ASME Section シ Division 1 When services temperatures are lower than -50⒌(-46∩).

1.4 Optional supplementary requirements are provided and, when one or more of these are desired, each shall be so stated in the order.

1.5 The values stated in inch-pound units are to be regarded as the standard.